Before delivering an engineering model, follow the method below to assure that the delivery is correct. 

This method works best with two screens.

Start by opening both the linked model in one Revit session on one screen and the Engineering model on the other screen in another Revit session


----------------------------------------------------------------------------

In the Linked model, which all the engineering requirements are linked to, use the Import from link tool to load all the parameter values from Import mapping and check that there is no warning.


----------------------------------------------------------------------------

Use transfer project standards to copy view templates from the engineering model to the Linked model.

Manage → Transfer project standard

Note: Make sure it is the engineering model in the drop-down on top.

Choose Check None and then check only View Templates.


----------------------------------------------------------------------------


If this dialogue shows, choose New Only 


----------------------------------------------------------------------------

Go to a floor view in the linked model and enable Temporary view properties.

It’s found at the bottom of each view.

Choose Temporary Apply Template Properties …

----------------------------------------------------------------------------

Select Fire_FireRating.

This helps to show all walls, doors, windows, and curtain walls that use FireReq parameters for Fire rating.

----------------------------------------------------------------------------

This helps to show all walls, doors, windows, and curtain walls that use FireReq parameters for Fire rating.

----------------------------------------------------------------------------

If a component does not have a color under the required symbol. In the Engineering model, select connect family and “re-connect” the symbol to the correct object.

The recommended workflow is to finish re-connecting a floor plan at the time.

When finished, save the engineering model.

----------------------------------------------------------------------------

In the Linked model, reload the Engineer model and import all data again. Repeat until the entire model has been colored.

When that is finished send the model to the recipient.




Create more view templates based on view filters to quality assure more parameter values such as Door magnets, 

Door openers, a requirement for re-enters, etc.